top of page
HVAC
7025 Holland Ave, Citrus Heights, CA 95621
Manufacturers Information
Unknown
Bonney Plumbing, LLC
Invoice 222876635
Invoice Date 7/30/2021
Technician Rhys Lucena-Jones
Ac Maintenance Temperature Split - 17 Changed / Cleaned filter Drain lines are clear
Tightened wires on the board
Blower Motor - Leaking oil (COMPROMISED, WHEN FAILED , NO AC)
Blower Capacitor-7.0/10MFD+-6%(OUT OF RANGE, WHEN FAILED NO AC) LRA - 92.1 / ? RLA - 7.6 / ? FLA - 0.6 / ? Washed condenser coil
Dual Capacitor - 7.6 / 7.5 MFD+-6% - Insulation: Blown Fiberglass 4 inches Duct Work: Grey Flex System is operational
Recommendations : - Capacitor - Blower Motor - Contactor - Compressor Saver -
Have a comfort advisor come out and go over the options of replacing the system, replacing duct work, and adding insulation
bottom of page