top of page
case study AC photo.jpg

Air Conditioner

2021 Alder Point Drive Roseville, CA 95661
Unit# 206

Manufacturers Information

Brand: Goodman Manufacturing Company

Model#: GSX130481BC

Serial#: 1401423394

Warranty: Not on file. Warranty Search Link

Voltage Range: 197-253

Max Circuit Breaker: 45

Min Circuit Amps: 26.4

Fan Motor: FLA 1.50 H.P. 1/4

Compressor RLA 19.9 LRA 109

Max Working Pressure: Unknown

Factory Charge OZ. R-410A: 104

Factory Test Pressure PSIG: 240-450

Part#: SR1439240

SR007

Jeff Gollaher 
Full Circle Home Inspections
6/27/2019
General Inspection

  • Recommend having the HVAC system serviced as part of the routine maintenance to help maintain the unit.

  • Functional at the time of the inspection.

Brower Mechanical
12/17/2019
Heating & Cooling Issue/Inspection

  • Customer complaint of no heat

  • Checked all safety devices

  • Ran system 

  • System would not start

  • Check diagnostic code and unit was blinking three which is a pressure switch stuck open 

  • Cleared and tested pressure switch and unit fired up

  • Tested from thermostat and unit is working

  • Recommend replacing pressure switch due to possible future failure.

  • Recommending sign up for RSA maintenance program.

  • Also talk to homeowners about ductwork issues. Returns are way too small for size of unit and the 12in duct is collapsed.

Ecology Air Innovations
06/06/2021
General Inspection/Estimate

  • Wire exposure. Attention recommended ASAP

  • Capacitor 1 overworked: Replacement recommended: 1 year part warranty.

  • Capacitor 2 overworked: Replacement recommended: 1 year part warranty.

  • Hard start kit recommended: 1 year part warranty.

  • Chemical wash recommended

Bonney Plumbing Heating and Air
07/08/2021
Gen. Maintenance/ Estimate

  • AC Tune up

  • Temp split: 20 degrees.

  • OEM Blower motor amps ( 7.36 / 8.1 ).

  • Blower capacitor 20uf +- 5% ( 18.76 ) lowest is 19**.

  • Blower motor hot to the touch.

  • No oil on blower motor. Tightened low volt wires on board.

  • Cleaned blower cabinet.

  • Inspected evaporator coil.

  • Flushed drain line.

  • RLA ( 13.29 / 19.9 ).

  • FLA ( .64 / 1.5 ).

  • LRA ( 119.4 / 109 ).

  • Dual run capacitor 45 + 5uf +- 5% ( 34.8 ) ( 4.66 ) lowest is 42.75 / 4.75***.

  • Contactor is good.

  • Some oil on condenser fan motor.

  • Cleaned inside / outside of system.

  • Condenser coil was super dirty.

  • Cleaned condenser coil.

  • Replaced 2 disposable filters.

  • Unit is operating at this time.


Recommendation:
Single run capacitor
Dual run capacitor
Compressor savor kit
Upgrade ductwork​

bottom of page